DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
| Symptom | Factor |
|---|---|
|
|
PROCEDURE
| 1. | CHECK AIR CONDITIONING SYSTEM |
(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.
| Blower Speed | Condition |
|---|---|
| LO → HI |
|
OK:
Airflow volume increases.
| NG |
| GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit) |
|
| 2. | CHECK ECO MODE SETTING |
(a) Check if the ECO mode indicator is off.
OK:
The ECO mode indicator is off.
| OK |
| GO TO STEP 4 |
|
| 3. | CHECK ECO MODE CONTROL OPERATION |
(a) Operate the ECO switch assembly (air conditioning control assembly) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.
HINT:
| Control | Outline |
|---|---|
| Blower Control | When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced. |
| Air Inlet Control | If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode. |
| Result | Proceed to |
|---|---|
| ECO mode indicator turns off and blower speed reduction is canceled | A |
| ECO mode indicator turns off, but the blower speed reduction is not canceled | B |
| ECO mode indicator does not turn off | C |
| B |
| REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| C |
| REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
|
| 4. | CHECK CLEAN AIR FILTER |
(a) Visually check the clean air filter.
Click here
OK:
The clean air filter is not dirty or clogged.
| NG |
| REPLACE CLEAN AIR FILTER |
|
| 5. | CHECK NO. 1 COOLER THERMISTOR |
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
The No. 1 cooler thermistor is installed correctly.
| NG |
| INSTALL NO. 1 COOLER THERMISTOR |
|
| 6. | CHECK ASPIRATOR |
(a) Check the installation condition of the aspirator.
OK:
The aspirator is installed correctly.
| OK |
| REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY |
| NG |
| INSTALL ASPIRATOR |
Blower Motor does not Operate
Recirculated/Fresh Air Modes Switch without User InputAutomatic transaxle: Shift the selector lever to the P position and set the parking brake.
Press the push button start to turn off the engine. The ignition position is off.