DESCRIPTION
When the stop and start system does not operate, check whether the operation is prohibited because the auxiliary battery conditions are not met.
Data List items Hood Courtesy Switch | Auxiliary Battery Current | Auxiliary Battery Fluid Temperature (Start) | Auxiliary Battery Fluid Temperature |
Idling Stop Rate | Total Idling Stop Rate | Integrated Current | Status of Auxiliary Battery Charge Control |
Minimum Voltage (Cranking) | Minimum Voltage (Starter Solenoid Engagement) | State of BBC | Stop&Start Operating Permission (Power Management) |
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Stop&Start Operating Permission (Integrated Current) | Stop&Start Operating Prohibition (Jump Start) |
Stop&Start Operating Prohibition (Manual Start for the First Time) | Auxiliary Battery Type | Ambient Temperature | Alternator Status |
NOTICE:
If the Data List item Stop&Start Operating Permission (Power Management) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the auxiliary battery charge amount being temporarily low or the auxiliary battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.
PROCEDURE
1. | CHECK MULTI-INFORMATION DISPLAY |
(a) Check whether the multi-information display displayed that the specified auxiliary battery is not equipped.
HINT:
The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified auxiliary battery when stop and start control is operated.
Result | Proceed to |
---|---|
No display | A |
Displayed in past | B |
B | GO TO STEP 14 |
|
2. | CHECK DTC OUTPUT |
(a) Read the DTCs.
Powertrain > Stop and Start > Trouble Codes Result | Proceed to |
---|---|
DTCs are not output | A |
DTCs are output | B |
B | GO TO DIAGNOSTIC TROUBLE CODE CHART |
|
3. | READ VALUE USING GTS (STOP&START OPERATING PERMISSION (POWER MANAGEMENT)) |
HINT:
Check whether stop and start control was prohibited based on the auxiliary battery conditions or other conditions.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Permission (Power Management) |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Permission (Power Management) | Permission of stop and start control based on the auxiliary battery conditions | NG / OK | OK: Stop and start control is permitted due to auxiliary battery condition, or Active Test (forced permission) is performed | - |
Result | Proceed to |
---|---|
NG is displayed | A |
OK is displayed | B |
B | END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS) |
|
4. | READ VALUE USING GTS (BATTERY TYPE) |
Tester Display |
---|
Battery Type |
(a) Check the "Battery Type" Data List Item.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery Other: Non-specified auxiliary battery | - |
(b) Check whether the auxiliary battery is specified or not specified.
GTS Display | Proceed to |
---|---|
Specified | A |
Other | B |
B | GO TO STEP 14 |
|
5. | READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START)) |
HINT:
Check whether stop and start control was prohibited based on the jump start auxiliary battery condition.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Prohibition (Jump Start) |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Permit: Except for jump start conditions | When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off. Jump start conditions: Engine started with the engine hood or back door open and the ignition switch turned START |
Result | Proceed to |
---|---|
Permit is displayed | A |
Prohibit is displayed | B |
HINT:
B | GO TO STEP 17 |
|
6. | READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (MANUAL START FOR THE FIRST TIME)) |
HINT:
Check whether the stop and start control was prohibited based on the manual start auxiliary battery condition.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Prohibition (Manual Start for the First Time) |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Prohibition (Manual Start for the First Time) | Prohibition of stop and start control based on the manual start conditions | Permit / Prohibit | Permit: Except for manual start conditions |
|
Result | Proceed to |
---|---|
Permit is displayed | A |
Prohibit is displayed | B |
B | END (STOP AND START CONTROL PROHIBITED DUE TO MANUAL START OPERATION) |
|
7. | READ VALUE USING GTS (STATE OF BBC) |
HINT:
Check the operation of the backup boost converter.
Powertrain > Stop and Start > Data List Tester Display |
---|
State of BBC |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
State of BBC | Backup boost converter status | Cycle Err / Overvoltage / Overload / Normal / Low Vol / Duty Err / Stop&Start Sensor Electric Supply Low / Stop&Start CPU Malfunction / BBC Overcurrent / Stop&Start Starter Overcurrent / Stop&Start Reduced Voltage Reset | Normal: Backup boost converter operating normally |
|
Result | Proceed to |
---|---|
Normal is displayed | A |
Normal is not displayed | B |
B | GO TO BACKUP BOOST CONVERTER CIRCUIT |
|
8. | READ VALUE USING GTS (ALTERNATOR STATUS) |
HINT:
Check the power generation status of the generator.
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Alternator Status | Generator power generation status | Normal /Abnormal | Normal: Generator operation normal | - |
Result | Proceed to |
---|---|
Normal is displayed | A |
Abnormal is displayed | B |
B | GO TO CHARGING SYSTEM |
|
9. | READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, IDLING STOP RATE AND TOTAL IDLING STOP RATE) |
HINT:
Check the idling stop rate.
Powertrain > Stop and Start > Data List Tester Display |
---|
Battery Fluid Temperature |
Idling Stop Rate |
Total Idling Stop Rate |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Fluid Temperature | Estimated temperature inside auxiliary battery | Min.: -40°C (-40°F) Max.: 215°C (419°F) | Changes according to actual temperature: Driving after engine warmed up | - |
Idling Stop Rate | Rate of the idling stop time to the entire ignition switch to ON time of this trip | Min.: 0% Max.: 255% | - | - |
Total Idling Stop Rate | Rate of the overall idling stop time to the overall ignition switch to ON time | Min.: 0% Max.: 255% | - | - |
Result | Proceed to | |
---|---|---|
Idling Stop Rate | Total Idling Stop Rate | |
40% or less | - | A |
Auxiliary battery fluid temperature 3°C (37°F) or higher: 50% or less | ||
Auxiliary battery fluid temperature 0 to 3 C (32 to 37°F):[(25 / 3) x Battery fluid temperature (°C) + 25]% or less | ||
- | Auxiliary battery fluid temperature Less than 0°C (32°F):[Battery fluid temperature (°C) + 25]% or less | |
Other than above | B |
B | END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE MORE THAN THRESHOLD OR TOTAL IDLING STOP RATE MORE THAN THRESHOLD) |
|
10. | READ VALUE USING GTS (AUXILIARY BATTERY FLUID TEMPERATURE, AMBIENT TEMPERATURE) |
HINT:
Check the auxiliary battery fluid temperature.
Powertrain > Stop and Start > Data List Tester Display |
---|
Battery Fluid Temperature |
Ambient Temperature |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Fluid Temperature | Estimated temperature inside auxiliary battery | Min.: -40°C (-40°F) Max.: 215°C (419°F) | Changes according to actual temperature: Driving after engine warmed up | - |
Ambient Temperature | Ambient temperature | Min.: -40°C (-40°F) Max.: 215°C (419°F) | Close to ambient temperature | - |
Result | Proceed to |
---|---|
Both Auxiliary Battery Fluid Temperature and Ambient Temperature are suitable temperature (Auxiliary Battery Fluid Temperature: -10°C (14°F) or higher and 70°C (158°F) or less, Ambient Temperature: -5°C (23°F) or higher) | A |
Auxiliary Battery Fluid Temperature or Ambient Temperature is not suitable temperature (Auxiliary Battery Fluid Temperature: -15°C (5°F) or less or 75°C (167°F) or higher, Ambient Temperature: -6°C (21.2°F) or less) | B |
HINT:
The Auxiliary Battery Fluid Temperature hysteresis is 5°C (9°F) and the Ambient Temperature hysteresis is 1°C (1.8°F).
B | END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL AUXILIARY BATTERY FLUID TEMPERATURE) |
|
11. | READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL) |
HINT:
Check whether stop and start control was prohibited based on the auxiliary battery charge control mode.
(a) Start the engine and allow it to idle.
Powertrain > Stop and Start > Data List Tester Display |
---|
Status of Battery Charge Control |
(b) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Status of Battery Charge Control | Auxiliary battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Auxiliary Battery Condition Judgment Mode / Low Temperature Mode | - | - |
Result | Proceed to |
---|---|
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed | A |
"Refresh Charge Mode" is displayed | B |
"Abnormal Mode" is displayed | C |
"Battery Condition Judgment Mode" is displayed* | - |
HINT:
*: When "Battery Condition Judgment Mode" is displayed, wait approximately 2 minutes for the mode to change and then check the value.
B | END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE) |
C | GO TO CHARGING SYSTEM |
|
12. | READ VALUE USING GTS (STOP&START OPERATING PERMISSION (MINIMUM VOLTAGE (STARTER SOLENOID ENGAGEMENT) AND MINIMUM VOLTAGE (CRANKING)) |
HINT:
Check whether stop and start control was prohibited based on the minimum starting voltage of the auxiliary battery condition.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Permission of stop and start control based on minimum voltage during starter solenoid engagement | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Permission of stop and start control based on minimum voltage during cranking | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
Result | Proceed to |
---|---|
OK is displayed for 2 items | A |
OK is displayed for 1 item or none | B |
HINT:
The Data List item "Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) and Stop&Start Operating Permission (Minimum Voltage (Cranking))" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List Tester Display |
---|
Minimum Voltage (Cranking) |
Minimum Voltage (Starter Solenoid Engagement) |
Battery Type |
Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V Max.: 327.67 V | 6 to 11 V | Lowest auxiliary battery voltage measured after the starter starts operating. |
Minimum Voltage (Starter Solenoid Engagement) | Minimum voltage when starter begins operation | Min.: -327.68 V Max.: 327.67 V | 6 to 11 V | Minimum auxiliary battery voltage while the starter starts operating. |
Battery Type | Set auxiliary battery | Specified / Other | Specified: Specified auxiliary battery Other: Non-specified auxiliary battery | - |
Permission Criteria (Specified Auxiliary Battery):
Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
---|---|---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 7.2 V or higher | - |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 7.2 V or higher |
Permission Criteria (Non-specified Auxiliary Battery):
Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
---|---|---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 8.92 V or higher | - |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 8.92 V or higher |
B | GO TO STEP 19 |
|
13. | READ VALUE USING GTS (STOP&START OPERATING PERMISSION (INTEGRATED CURRENT)) |
HINT:
Check whether stop and start control was prohibited based on the integrated current value auxiliary battery condition.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Permission (Integrated Current) |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Permission (Integrated Current) | Permission of stop and start control based on the integrated current value conditions | NG / OK | OK: Integrated current value is equal to the threshold or more | The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the auxiliary battery fluid temperature. |
Result | Proceed to |
---|---|
OK is displayed | A |
NG is displayed | B |
A | END (TURN ELECTRICAL LOAD OFF AS MUCH AS POSSIBLE) |
B | GO TO STEP 16 |
14. | CHECK AUXILIARY BATTERY SETTINGS AND EQUIPPED AUXILIARY BATTERY |
Tester Display |
---|
Battery Type |
(a) Check the "Auxiliary Battery Type" Data List Item.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery Other: Non-specified auxiliary battery | - |
(b) Check whether the auxiliary battery is specified or not specified.
Data List Auxiliary Battery Type Display | Equipped Auxiliary Battery | Proceed to |
---|---|---|
Other | Specified auxiliary battery | A |
Other | Non-specified auxiliary battery | B |
B | EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT AUXILIARY BATTERY MALFUNCTION WHEN A NON-SPECIFIED AUXILIARY BATTERY IS USED |
|
15. | SWITCH BATTERY TYPE |
Tester Display |
---|
Switch Battery Type |
(a) Perform Switch Auxiliary Battery Type under Utility and set the Specified auxiliary battery.
Powertrain > Stop and Start > Data List Tester Display |
---|
Battery Type |
(b) Check that the "Auxiliary Battery Type" Data List item is set to "Specified".
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery Other: Non-specified auxiliary battery | - |
NEXT | END |
16. | READ VALUE USING GTS (INTEGRATED CURRENT) |
HINT:
Judge the auxiliary battery condition based on the integrated current value.
Powertrain > Stop and Start > Data List Tester Display |
---|
Integrated Current |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Integrated Current | Auxiliary battery integrated current | Min.: -268434.456 Asec Max.: 268435.4558 Asec | Differs according to the vehicle condition (charge/discharge conditions) | - |
HINT:
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
Powertrain > Stop and Start > Data List Tester Display |
---|
Battery Current |
Integrated Current |
Status of Battery Charge Control |
Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Current | Auxiliary battery current | Min.: -125 A Max.: 124.9961 A | - | - |
Integrated Current | Auxiliary battery integrated current | Min.: -268434.456 Asec Max.: 268435.4558 Asec | Differs according to vehicle condition (charge/discharge conditions) | - |
Status of Battery Charge Control | Auxiliary battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode | - | - |
Standard Integrated Current Value:
Status of Auxiliary Battery Charge Control | Integrated Current | Proceed to |
---|---|---|
Charge Control Coordination Mode, Stop and Start Standalone Mode and Low Temperature Mode | Below -15444 A-sec | A |
Stop and Start Restriction Mode and Temperature High/Low Mode | Below 0 A-sec | B |
Cause and Action to be Taken:
Result | Cause | Action to be Taken |
---|---|---|
A | Integrated current value is limited for the stop and start control due to discharge or deterioration of the auxiliary battery | Check the auxiliary battery condition and recharge the auxiliary battery |
B |
|
|
*: Use the GTS to perform Integrated Current Value Initialization.
Click here
HINT:
If the Data List item "Integrated Current" is 0 A-sec or higher, it is not necessary to perform initialization.
NEXT | CHARGE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE |
17. | READ VALUE USING GTS (HOOD COURTESY SWITCH) |
HINT:
Check the engine hood courtesy switch (hood lock assembly).
Powertrain > Stop and Start > Data List Tester Display |
---|
Hood Courtesy Switch |
(a) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed OFF: Engine hood open | - |
Result | Proceed to |
---|---|
When engine hood condition changes from open to closed, Data List switches from OFF to ON | A |
When engine hood condition changes from open to closed, Data List remains OFF | B |
HINT:
If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
B | GO TO ENGINE HOOD COURTESY SWITCH CIRCUIT (OPERATION PROHIBITED AS ENGINE HOOD STATE DOES NOT CHANGE TO CLOSE) |
|
18. | READ VALUE USING GTS (STOP&START OPERATING PROHIBITION (JUMP START)) |
(a) Check that the engine hood and back door are closed.
(b) Turn the ignition switch off and wait for 30 seconds or more.
Powertrain > Stop and Start > Data List Tester Display |
---|
Stop&Start Operating Prohibition (Jump Start) |
(c) Check that the Data List item "Stop&Start Operating Prohibition (Jump Start)" displays "Permit".
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Permit: Except for jump start conditions |
|
HINT:
NEXT | END |
19. | CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE |
(a) Check the auxiliary battery.
Click here
HINT:
(b) Check the starter inrush current reduction relay.
Click here
(c) Start the engine.
Powertrain > Stop and Start > Data List Tester Display |
---|
Battery Current |
(d) According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Battery Current | Auxiliary battery current | Min.: -125 A Max.: 124.9961 A | - | - |
(e) While idling, illuminate the headlights (Lo).
HINT:
The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.
(f) Charge the auxiliary battery for approximately 5 minutes after Auxiliary battery Current drops to 5 A or less.
HINT:
The Data List item Auxiliary battery Current decreases when the battery is charged. If the auxiliary battery is charged for 5 minutes after Auxiliary battery Current drops to 5 A or less, it can be determined that the auxiliary battery is sufficiently charged.
(g) Turn off the headlights.
(h) Turn the ignition switch off and wait for 30 seconds or more.
(i) Start the engine and check the following Data List items.
Powertrain > Stop and Start > Data List Tester Display |
---|
Minimum Voltage (Cranking) |
Minimum Voltage (Starter Solenoid Engagement) |
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) |
Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
---|---|---|---|---|
Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V Max.: 327.67 V | 6 to 11 V | Lowest auxiliary battery voltage measured after the starter starts operating. |
Minimum Voltage (Starter Solenoid Engagement) | Minimum voltage when starter begins operation | Min.: -327.68 V Max.: 327.67 V | 6 to 11 V | Minimum auxiliary battery voltage while the starter starts operating. |
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Permission of stop and start control based on minimum voltage during starter solenoid engagement | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Permission of stop and start control based on minimum voltage during cranking | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
Permission Criteria (Specified Auxiliary Battery):
Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
---|---|---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 7.2 V or higher | - |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 7.2 V or higher |
Permission Criteria (Non-specified Auxiliary Battery):
Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
---|---|---|
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 8.92 V or higher | - |
Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 8.92 V or higher |
(j) Replace the auxiliary battery in the following situations.
NEXT | CHECKING BATTERY STATE |
Before refueling, close all the doors, windows, and the liftgate/trunk lid, and switch the ignition OFF.
To open the fuel-filler lid, pull the remote fuel-filler lid release.To remove the fuel-filler cap, turn it counterclockwise. Attach the removed cap to the inner side of the fuel-filler lid.