Toyota Yaris: Air Conditioning System / Ambient Temperature Sensor Circuit Short to Battery or Open (P007015)

Toyota Yaris XP210 (2020-2024) Reapir and Service Manual / Vehicle Interior / Heating / Air Conditioning / Air Conditioning System / Ambient Temperature Sensor Circuit Short to Battery or Open (P007015)

DESCRIPTION

The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The combination meter assembly applies voltage (5 V) to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly. The air conditioning amplifier assembly communicates with the combination meter assembly via CAN communication. The combination meter assembly sends ambient temperature signal to the air conditioning amplifier assembly.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

Memory

P007015

Ambient Temperature Sensor Circuit Short to Battery or Open

Diagnosis Condition:

  • Ignition switch ON

Malfunction Status:

  • Open or short in ambient temperature sensor circuit

Detection Time:

  • Continuously for 4 seconds or more
  • Thermistor assembly
  • Harness or connector
  • Combination meter assembly
  • Air conditioning amplifier assembly

Memorized

DTC Detection Condition Combination Table
 

Vehicle Condition

Pattern 1

Pattern 2

Diagnosis Condition

Ignition switch ON

Malfunction

Open in ambient temperature sensor circuit

-

Short in ambient temperature sensor circuit

-

Detection Time

Continuously for 4 seconds or more

Continuously for 4 seconds or more

Trip Count

1 trip

1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored

WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:

  • The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.

    Click here

  • When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.

PROCEDURE

1.

READ VALUE USING GTS (AMBIENT TEMPERATURE SENSOR)

(a) Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Ambient Temperature Sensor

Thermistor assembly

Min.: -327.68°C (-557.82°F)

Max.: 327.67°C (621.81°F)

Actual ambient temperature displayed

Thermistor assembly circuit malfunction

Body Electrical > Air Conditioner > Data List

Tester Display

Ambient Temperature Sensor

OK:

The display is as specified in the normal condition column.

OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.

INSPECT THERMISTOR ASSEMBLY

Click here

NG

REPLACE THERMISTOR ASSEMBLY

OK

3.

CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - COMBINATION METER ASSEMBLY)

(a) Disconnect the H6 combination meter assembly connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A52-1 (SO-) - H6-11 (TX1-)

Always

Below 1 Ω

A52-2 (SO+) - H6-16 (TX1+)

Always

Below 1 Ω

A52-1 (SO-) or H6-11 (TX1-) - Other terminals and body ground

Always

10 kΩ or higher

A52-2 (SO+) or H6-16 (TX1+) - Other terminals and body ground

Always

10 kΩ or higher

OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

    Ambient Temperature Sensor Circuit Short to Ground (P007011)

    DESCRIPTION The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system...

    Refrigerant Pressure Sensor Circuit Short to Ground (P053011)

    DESCRIPTION The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly...

    Other information:

    Toyota Yaris XP210 (2020-2024) Reapir and Service Manual: Driver Side Door Entry Unlock Function does not Operate


    DESCRIPTION If the entry unlock function does not operate for the driver door only, but the entry lock function operates, the request code is being transmitted properly from the driver door. In this case, there may be a problem related to the unlock sensor (connection between the certification ECU (smart key ECU assembly) and front door outside handle assembly LH)...

    Toyota Yaris XP210 (2020-2024) Reapir and Service Manual: Removal


    REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the steering angle sensor removal/installation are shown below...

    Categories

    Fuel Gauge

    The fuel gauge shows approximately how much fuel is remaining in the tank when the ignition is switched ON. We recommend keeping the tank over 1/4 full.

    Toyota Yaris. Fuel Gauge

    Full 1/4 Full Empty

    read more

     
    Copyright © 2024 www.toyaris4.com